F....counting no. per region 1-4<br/>
 
F....counting no. per region 1-4<br/>
 
R....Region 1-9 (in OE it is the state 1-9 in DL the first position of the postal code)<br/>
 
R....Region 1-9 (in OE it is the state 1-9 in DL the first position of the postal code)<br/>
LL...country code - only the last both digits - (OE...2<32>    DL...2<62>    HB9...2<28>)<br/>
+
LL...country code - only the last both digits - (OE...2<32>    DL...2<62>    HB9...2<28>  US...3<10>)<br/>
  
So hat z.B.:<br/>
+
e.g.:<br/>
der zweite Repeater in OE8 '''62832''' oder<br/>
+
the second repeater in region 8 in OE '''62832''' or<br/>
der dritte  Repeater in DL Plz.Gebiet 4 '''63462'''
+
the third repeater in postal region 4 in DL '''63462''' or<br/>
 +
the forth repeater in region 7 in US'''64710'''<br/>
  
== Zeitschlitze / Sprechgruppen ==
+
== Timeslots / Talkgroups ==
* LOKAL - Der Zeitschlitz TS1 ist komplett lokal gehalten. Bitte TG9 verwenden aus Kompatibilität.<br/>
+
* local QSOs - the timeslot TS1 should be complete free for local QSOs. Please use TG9 to be compatible to the network issues.<br/>
* ECHO - Als Besonderheit am Zeitschlitz TS1 gibt es eine Echo Funktion. Alles was auf TG9990 gesprochen wird, wird nach loslassen der PTT wiederholt.<br/>
+
* echo function- as a special we offer on TS1 a echo function. All you speek to TG9990 on TS1 will be responded after release of PTT.<br/>
* NATIONAL - Der Zeitschlitz TS2 ist mit TG9 auch für lokal benützbar. Mit TG232 ist OE weite Verbindung möglich<br/>
+
* national QSOs - the timeslot TS2 with TG9 you can also use for local QSOs. With your country code (e.g. in OE TG232 or TG3 in USA) you can make nation wide QSOs<br/>
* INTERNATIONAL Mit TG1 ist internationale Vernetzung (dzt. DL ca. 5 Repeater) möglich.<br/>
+
* international QSOs with TG1 you are connected to all repeaters WW (US, EU, ...).<br/>
  
 
== LastHeard ==
 
== LastHeard ==
via http://87.106.3.249/dmr kann eine LastHeard Liste abgefragt werden. Diese wird noch in die allgemeine DMR LastHeard Liste eingefügt.
+
via http://87.106.3.249/dmr you can see the list of the last heard QSOs.
  
== Software Erweiterungen ==
+
== WinMaster Software ==
Die Software wurde von Torsten DG1HT übernommen und für den OE-MASTER angepasst.<br/>
+
The WinMaster software ist wirtten with .NET C# and connect the repeaters to the network..<br/>
Da diese Software komplett von Amateuren geschrieben wird können in Kürze folgende Features realisiert werden:
+
With In der Parametermaske werden die Routen eingetragen. Es wird auch festgelegt welche Zeitschlitze benutzt werden.<br/>
* CALL-Sign Routing (Das Programm verbindet automatisch mit dem Zielrepeater)
 
* Repeater Routing (nur die für das QSO erforderlichen Repeater sind in Betrieb)
 
* dynamische Repeater Gruppen (Repeater können vom User dynamisch zusammen geschalten werden)
 
 
 
== OE-MASTER ONLINE ==
 
Die OE-MASTER Software ist in .NET C# programmiert und ist für das Routing der HYTERA Repeater zuständig.<br/>
 
In der Parametermaske werden die Routen eingetragen. Es wird auch festgelegt welche Zeitschlitze benutzt werden.<br/>
 
 
Weiters legt der OE-MASTER auch fest wie der nächste MASTER Server erreicht werden kann.<br/>
 
Weiters legt der OE-MASTER auch fest wie der nächste MASTER Server erreicht werden kann.<br/>
 
Über diese Struktur können Regionen, Länder und Kontinente im Routing erreicht werden.<br/>
 
Über diese Struktur können Regionen, Länder und Kontinente im Routing erreicht werden.<br/>

Version vom 31. August 2013, 09:14 Uhr

WINMASTER

by: Kurt OE1KBC oe1kbc@oevsv.at

On the ÖVSV server we installed the DMR OE-MASTER and you can use this master for testing issues.

You can connect with HYTERA RD985 or RD965 repeater with the IP Multi-Site Service license installed. The connection is done via the "Supermaster" service.

Parameters

  • Repeater Type: IP Multi-Site Master
  • Jitter Buffer Length: 3
  • Authentication Key: !! leave empty !!
  • IP Multi-site Networking UDP Port: 62015
  • P2P Firewall Open Time (sec): 6
  • IP Multi-Site Service: checked
  • IP Multi-Site Service UDP Port: 62016
  • RDAC: unchecked
  • Super Master Service: checked
  • Super Master IP: 178.188.156.53
  • Super Master UDP Port: 62005
  • Super Master Multi-Site Service: checked
  • Super Master Multi-Site UDP Port: 62006

Please note: Use the UDP-Port "62006" only for the first tests and QSOs. After that you will get a fixed UDP-Port. This Port identify you repeater to routing- and informations systems.
Only with a fix UDP-Port you can use all the features in the WinMaster system. You can get this fix port form your WinMaster administrator. In Austria please contact me oe1kbc@oevsv.at

Server ID

The HYTERA Repeaters to not give their ID to the network streams so i've to take this information from "Super Master Multi-Site UDP" Port.
Therefore, if you use the default UPD-Port 62006 no Server-ID can be calculated.
In coordination with Torsten DG1HT (for BMaster and SMaster) and OE1KBC (for WinMaster) we have the following posibilities:
Super Master Multi-Site UDP Port: 6FRLL
6....fix
F....counting no. per region 1-4
R....Region 1-9 (in OE it is the state 1-9 in DL the first position of the postal code)
LL...country code - only the last both digits - (OE...2<32> DL...2<62> HB9...2<28> US...3<10>)

e.g.:
the second repeater in region 8 in OE 62832 or
the third repeater in postal region 4 in DL 63462 or
the forth repeater in region 7 in US64710

Timeslots / Talkgroups

  • local QSOs - the timeslot TS1 should be complete free for local QSOs. Please use TG9 to be compatible to the network issues.
  • echo function- as a special we offer on TS1 a echo function. All you speek to TG9990 on TS1 will be responded after release of PTT.
  • national QSOs - the timeslot TS2 with TG9 you can also use for local QSOs. With your country code (e.g. in OE TG232 or TG3 in USA) you can make nation wide QSOs
  • international QSOs - with TG1 you are connected to all repeaters WW (US, EU, ...).

LastHeard

via http://87.106.3.249/dmr you can see the list of the last heard QSOs.

WinMaster Software

The WinMaster software ist wirtten with .NET C# and connect the repeaters to the network..
With In der Parametermaske werden die Routen eingetragen. Es wird auch festgelegt welche Zeitschlitze benutzt werden.
Weiters legt der OE-MASTER auch fest wie der nächste MASTER Server erreicht werden kann.
Über diese Struktur können Regionen, Länder und Kontinente im Routing erreicht werden.
Natürlich ist auch ein zentraler Server für die Darstellung der LastHeard Informationen angebbar.
Das System wir durch diese Struktur sehr dynamisch gehalten und erfordert keine großartigen Struktur-Planungen.

Hier ein Bild vom ÖVSV HYTERA-DMR OE-MASTER

OPEN HYTERA OE MASTER

Fragen zu OE-MASTER

Bei Fragen zum Server: EMail an oe1kbc@oevsv.at

Diskussionen

Anhänge